蜜桃久久黄网站,蜜桃导航在线网站,水蜜桃无码视频,蜜桃视频免费下载APP官方

    What are the national standards for ozone detectors?

    Views :
    Update time : 2025-08-08

    What are the national standards for ozone detectors?


    20240921-121606.jpg

    With the tightening of environmental protection policies and the enhancement of health awareness, the demand for ozone detectors in industrial safety, environmental monitoring and household scenarioses has soared. To ensure the accuracy and compliance of equipment, the state has updated a number of national standards. The core standards of ‌ include ‌ :


    I. ‌ Chinese National Standard (Mandatory/Recommended) ‌


    Youdaoplaceholder0 1.GB/T 18883-2025 Indoor air quality standard ‌


    Youdaoplaceholder0 Core content ‌ :


    Ozone concentration limit: 1-hour average ≤0.16mg/m³ (approximately 0.08ppm).


    Requirements for the testing instrument: accuracy ±5%, range 0-0.5ppm.


    Youdaoplaceholder0 applicable scenarioses ‌ : air quality monitoring in homes, offices and public places.




    2‌.GB 12358-2023 "Ozone Detection and Alarm Instrument for Workplaces" ‌


    Youdaoplaceholder0 Core content ‌ :


    Ozone safety threshold for industrial scenarioses: 8-hour average ≤0.1ppm, short-term exposure ≤0.3ppm.


    Instrument requirements: Explosion-proof certification, sound and light alarm, error ≤±3%.


    Youdaoplaceholder0 applicable scenarioses ‌ : industrial environments such as chemical engineering, printing, water treatment, etc.




    3‌.GB/T 37820-2025 Technical specification for electrochemical Ozone detector ‌


    Youdaoplaceholder0 Core content ‌ :


    The sensor life is no less than 2 years, and the calibration cycle is no more than 6 months.


    Data storage ≥ 10,000 entries, supporting Bluetooth /WiFi transmission.


    Ii. Youdaoplaceholder0 Environmental Protection and Industry Standards ‌


    Youdaoplaceholder0 1.HJ 590-2024 Technical Specification for Automatic Monitoring of Ozone in Ambient air ‌


    Youdaoplaceholder0 Core content ‌ :


    The ultraviolet absorption method is used as the reference method, with a resolution of ≤0.001ppm.


    It should have the function of temperature/humidity compensation.



    Youdaoplaceholder0 2.JB/T 12955-2025 General Specification for Ozone Detectors for industrial use ‌


    Youdaoplaceholder0 Core content ‌ :


    Dust and water resistance grade ≥IP65, response time ≤15 seconds.


    Supports multi-gas module expansion (such as VOCs, CO₂).


    Iii. Youdaoplaceholder0 International standard reference ‌


    Youdaoplaceholder0 1. ISO 16000-38:2025 "indoor air - methods for ozone detection" ‌


    The ultraviolet light absorption method is required, with an error within ±2%.


    Youdaoplaceholder0 2.EPA 40 CFR Part 50 (EPA) ‌ : Certification standard for ozone monitoring equipment.


    Iv. Dynamics of New Standards Added in 2025 ‌


    Youdaoplaceholder0 Intelligent Internet of Things requirements ‌ : Add data encryption and remote calibration protocols (such as GB/T 2025-xxxx).


    Youdaoplaceholder0 Green manufacturing standards ‌ : energy consumption and material recovery rate limits in the production process (e.g. HJ 1102-2025).


    V. ‌ Selection and Compliance Advice ‌


    Youdaoplaceholder0 priority matching scenario ‌ :


    For home use, choose ‌GB/T 18883-2025‌ certified model.


    Industrial selection ‌GB 12358-2023‌ + ‌ explosion-proof certification ‌ (e.g. Ex ib IIB T4).


    Youdaoplaceholder0 Verification mark ‌ : Check the "CMA" or "CNAS" test report number on the product nameplate.


    Youdaoplaceholder0 Local requirements ‌ : In regions such as the Beijing-tianjin-hebei area and the Yangtze River delta, additional ‌ regional environmental protection standards ‌ (such as AQI linked alarm) may be added.


    Appendix: A Guide to Avoiding Pitfalls


    ❗ beware of "conforming to old national standards" (such as GB/T 18883-2002 which has been abolished).


    ❗ international brands need to confirm the Chinese localization certification (such as CCC compulsory certification) additionally.


    Related News
    Read More >>
    Introduction to the Light Sour Introduction to the Light Sour
    08 .05.2026
    Introduction to the Light Source Structure of UV Ozone AnalyzersUV absorption is
    Online vs Offline Dissolved Oz Online vs Offline Dissolved Oz
    08 .05.2026
    Online vs Offline Dissolved Ozone Monitoring: Pros and ConsDissolved ozone is wi